The main components are a reservoir (single or multiple), liquid-filled tubing and a vibrating wire pressure transducer cell mounted on a plate or, for borehole application, attached to an anchor.
The vibrating wire sensor is attached to a settlement plate at the point of estimated settlement. The sensor is connected via two liquid-filled tubes which are connected to a reservoir located on stable ground.
As the transducer settles with the surrounding ground the height of the column is increased and the corresponding higher pressure is measured by the transducer.
Settlements are calculated by converting the pressure to millimetres of liquid head.
Applications:
| Subsurface point settlements/heave beneath | |
| Embankments | |
| Surcharges | |
| Fills | |
| Dams | |
| Landfills |
Features:
| Not affected by barometric pressure | |
| In-situ checks available | |
| Air can be easily removed | |
| Manual or automated readout | |
| Reservoir can be sited away from construction area |